Key Specifications
| Feature | Specification |
|---|---|
| Model Variants | LCA-D (with display and keypad), LCA-X (without display) |
| A/D Converter | 24-bit resolution |
| Display Resolution | 1/100,000 (optional 1/1,000,000) |
| Input Range | -1.60 V to +1.60 V |
| A/D Conversion Rate | 50 samples per second |
| Display | LCD, 2×16 characters |
| Maximum Range | 7-digit display (-9,999,999 to +9,999,999) |
| Load Cell Support | Connects up to 8 load cells |
| Communication Interfaces | RS-232C / RS-485 (selectable) |
| Power Supply | 12–24 V DC/AC |
| Protection Class | IP66 (dust-tight and protected against powerful water jets) |
| Housing | Aluminum cast housing suitable for dusty, humid, and corrosive environments |
| Calibration | Supports digital linearization (5 areas with 6 points) and temperature correction |
| Remote Monitoring | Enables remote monitoring of measurements via connected systems |
Where it is used
A weighing indicator powers the load cells, reads their signal and shows the weight. This model suits platform, floor and bench scales. Browse digital & modbus weighing indicators or all weighing indicators.
Installation and calibration
After an indicator is fitted, the scale must be calibrated, and a trade scale verified and stamped. Our technicians install indicators and calibrate scales on site through our calibration and repair services. Request a quote.
Frequently asked questions
Most analogue load cells work with it. Tell us your load cell type and number of cells and we will confirm.
Yes, if the model has the output you need (for example RS232 or Bluetooth). Check the specifications or ask us.
Yes. We fit the indicator, calibrate the scale and support it across Kenya.