Where it is used
A compression load cell suits weighbridges, silos and heavy tanks. It needs a compatible digital indicator, such as the ESIT ECI Digital indicator. Browse all load cells.
Fitting and calibration
Match the type, mounting, capacity, signal and accuracy class to the cell you are replacing. After a load cell change the scale must be recalibrated, and a trade scale re-verified and stamped. Our technicians fit load cells and recalibrate on site through our calibration and repair services. Request a quote.
Frequently asked questions
It is, if the type, mounting, capacity, signal (digital) and accuracy class match. Send us the label details or a photo of your current cell and we will confirm.
Yes. The scale must be recalibrated, and a scale used for trade must be re-verified and stamped.
Only with an indicator that supports this digital load cell. Replace like-for-like, or tell us your indicator model and we will check.
Yes. Our technicians fit load cells and recalibrate scales and weighbridges across Kenya.