Specifications
| Specification | Value |
|---|---|
| Capacities (Emax) | 25,000 kg and 125,000 kg |
| Accuracy class (OIML R60) | C3 (3,000 intervals) / C4 (4,000 intervals) |
| Minimum verification interval | Emax/20,000 (C3) / Emax/24,570 (C4) |
| Combined error | ≤ ±0.02% (C3) / ≤ ±0.012% (C4) |
| Creep error over 30 min | ≤ ±0.0060% Emax (C3) / ≤ ±0.0055% Emax (C4) |
| Minimum load | 0% Emax |
| Maximum safe overload | 150% Emax |
| Maximum safe side load | 100% Emax |
| Ultimate load | 300% Emax |
| Deflection at Emax | ≤ 0.3 mm |
| Excitation voltage | 12–24 V |
| Excitation current | 50 mA |
| Output signal at nominal load | 200,000 counts |
| A/D converter | 24-bit sigma-delta, 1 or 200 Hz |
| Data interface | Semi-duplex RS485, Modbus, 115,200 baud |
| Angle measurement error | 0.1° |
| Insulation voltage | 2,500 V |
| Compensated temperature range | −10 to +40 °C |
| Operating temperature range | −40 to +80 °C |
| Material | Steel alloy, corrosion-retardant paint |
| Sealing (EN 60529) | IP68 |
| Weight | 22.5 kg |
| Package | 25 × 33 × 23 cm, 24.5 kg |
Source: ESIT Elektronik HSCD datasheet.
Where it is used
High-capacity truck weighbridges, railway scales, silos and heavy tanks. It needs a digital indicator that supports ESIT digital load cells, such as the ESIT ECI Digital indicator. Browse all load cells and weighbridges.
Fitting and calibration
Replace like-for-like so the indicator recognises the cell. After a load cell change the weighbridge must be recalibrated and re-verified for trade. Our technicians do this on site through our calibration and repair services. Request a quote.
Frequently asked questions
25,000 kg and 125,000 kg, in accuracy classes C3 and C4.
Each cell reports its own reading over RS485 Modbus, so a faulty cell can be found quickly and corners adjusted digitally, without a trimming junction box.
Only with an indicator that supports ESIT digital load cells, such as the ESIT ECI Digital. Tell us your indicator model and we will check.
Yes. It is IP68 rated and fully immersible, suited to weighbridge pits that flood.