Mavin NA3 300 kg Single Point Load Cell

The Mavin NA3 300 kg is a single point load cell for bench and platform scales, rated to OIML C3 with a 2.0 mV/V output. Full specifications are in the table below.

0.00 KSh 0.00 KSh (Tax excluded)




Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days




Key Specifications for Mavin NA3 – 300 kg

FeatureSpecification
Rated Capacity300 kg
Rated Output2.0 mV/V ±5%
Zero Balance±0.0200 mV/V
Accuracy ClassOIML C3 (up to 3000 divisions)
Non-linearity≤0.017% of rated output
Hysteresis≤0.017% of rated output
Repeatability≤0.017% of rated output
Creep (30 minutes)≤0.017% of rated output
Temperature Effect on Output0.0015% of rated output per °C
Temperature Effect on Zero0.002% of rated output per °C
Input Impedance410 Ω ±15 Ω
Output Impedance350 Ω ±5 Ω
Insulation Resistance≥5000 MΩ at 50 VDC
Recommended Excitation Voltage5–12 VDC
Maximum Excitation Voltage15 VDC
Safe Overload150% of rated capacity
Ultimate Overload200% of rated capacity
Operating Temperature Range-20°C to +60°C
MaterialAluminum alloy
Protection ClassIP66/IP67
Cable5 mm diameter, 2 m length
Recommended Platform SizeUp to 600 × 800 mm
Dimensions174 × 60 × 64 mm

Where it is used

A single point load cell suits bench, retail and small platform scales, where one cell sits under the centre of the platform. It connects through a junction box to an analogue weighing indicator. Browse all load cells.

Fitting and calibration

Match the type, mounting, capacity, signal and accuracy class to the cell you are replacing. After a load cell change the scale must be recalibrated, and a trade scale re-verified and stamped. Our technicians fit load cells and recalibrate on site through our calibration and repair services. Request a quote.

Frequently asked questions

It is, if the type, mounting, capacity, signal (analogue) and accuracy class match. Send us the label details or a photo of your current cell and we will confirm.

Yes. The scale must be recalibrated, and a scale used for trade must be re-verified and stamped.

On a multi-cell scale you need a junction box and an analogue indicator. See our junction boxes and weighing indicators.

Yes. Our technicians fit load cells and recalibrate scales and weighbridges across Kenya.

Recently Viewed Products

 
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.
Scalestech
Online
Hi there 👋

We're glad you're here. Let us know how we can assist you—we're ready to provide the best solutions for your needs!
Call us