Models;
| Model | Capacities | Minumum Division | Maximum Overload Capacity |
| SBS 200 | 200 kg | 20 g | 300 kg |
| SBS 500 | 500 kg | 50 g | 750 kg |
| SBS 1000 | 1000 kg | 100 g | 1500 kg |
| SBS 2000 | 2000 kg | 200 g | 3000 kg |
Specifications;
| Maximum capacities (Emax) | kg | 200,500,1000,2000 | ||
| Accuracy (OIML R60) |
| |||
Maximum number of verification intervals ( ) |
| |||
Minimum verification interval ( ) |
| |||
| Combined error | % | ≤ ±0.05 ≤ ±0.02 | ||
| Creep error over 30 min. (DR) | %Emax | 0.00625 | ||
| Minimum load | %Emax | 0 | ||
| Maximum safe overload | %Emax | 150 | ||
| Maximum safe sideload | %Emax | 100 | ||
| Ultimate load | %Emax | 300 | ||
| Stretching (Emax) | mm | ≤0.3 | ||
| Maximum excitation voltage (Umax) | V | 15 | ||
| Rated output (Cn) | mV/V | 2 ±0.1% | ||
| Zero balance | %Cn |
| ||
| Input Resistance | Ω | 385 ±20 | ||
| Output Resistance | Ω | 351±3 | ||
| Insulation resistance | MΩ | ≥500 | ||
| Compensated temperature range | °C | -10...+40 | ||
| Operating temperature range | °C | -40...+80 | ||
| Load cell material | Stainless Steel | |||
| Sealing (EN60529) | IP68 | |||
| Cable length | m | 5±%3 | ||
| Cable diameter | mm | 5 | ||
| Weight | kg | 1.1 | ||
| Package dimensions / weight | cm/kg | 10x27x6/1.2 |
Where it is used
A shear beam load cell suits platform and floor scales, tank and hopper weighing. It connects through a junction box to an analogue weighing indicator. Browse all load cells.
Fitting and calibration
Match the type, mounting, capacity, signal and accuracy class to the cell you are replacing. After a load cell change the scale must be recalibrated, and a trade scale re-verified and stamped. Our technicians fit load cells and recalibrate on site through our calibration and repair services. Request a quote.
Frequently asked questions
It is, if the type, mounting, capacity, signal (analogue) and accuracy class match. Send us the label details or a photo of your current cell and we will confirm.
Yes. The scale must be recalibrated, and a scale used for trade must be re-verified and stamped.
On a multi-cell scale you need a junction box and an analogue indicator. See our junction boxes and weighing indicators.
Yes. Our technicians fit load cells and recalibrate scales and weighbridges across Kenya.
)
)